• Hve-P249heat Pump Vacuum Evaporator, 250L/T Negative Pressure Heat Pump Evaporator
  • Hve-P249heat Pump Vacuum Evaporator, 250L/T Negative Pressure Heat Pump Evaporator
  • Hve-P249heat Pump Vacuum Evaporator, 250L/T Negative Pressure Heat Pump Evaporator
  • Hve-P249heat Pump Vacuum Evaporator, 250L/T Negative Pressure Heat Pump Evaporator
  • Hve-P249heat Pump Vacuum Evaporator, 250L/T Negative Pressure Heat Pump Evaporator
  • Hve-P249heat Pump Vacuum Evaporator, 250L/T Negative Pressure Heat Pump Evaporator

Hve-P249heat Pump Vacuum Evaporator, 250L/T Negative Pressure Heat Pump Evaporator

After-sales Service: Remote Assistance
Warranty: 1year
Type: Distillation Equipment
Object: Swage
Separation Mode: Evaporation and Concentration
Operating Type: Continuous Type
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
HVE-P249
Installation
Vertical
Centrifuge Type
Evaporation and Concentration
Distillation Equipment Type
Essential Oil Distillation Equipment
Extraction Tower Type
Vibration Plate Tower
Pressure
Negative Pressure
Condition
New
Transport Package
Export Packing
Specification
1450*700*1700mm
Trademark
LIHEDA
Origin
China
HS Code
8419899090
Production Capacity
100cover/Year

Product Description


Hve-P249heat Pump Vacuum Evaporator, 250L/T Negative Pressure Heat Pump Evaporator
HVE series heat pump vacuum evaporator
model:HVE-P249 Daily processing capacity:MAX 250L Manufacturer: Liheda (Dongguan) environmental protection equipment
Hve-P249heat Pump Vacuum Evaporator, 250L/T Negative Pressure Heat Pump Evaporator

 
Liheda (Dongguan) Environmental Protection Equipment Co., Ltd
Sewage Treatment Equipment Based on the Combination of Heat Pump Technology and Vacuum Technology -- Heat Pump Low Temperature Evaporator
1st Floor, Building 6, Songyuan Innovation Technology City, Junda West Road, Dongkeng Town, Dongguan City, Guangdong Province
  Wang Dewei      13829249131
 
  1. Technical features:
Processing capacity of water-based liquid: 250L/24h
Distillation chamber material (sewage contact): SUS304(Available in 316 2205 2507 )
Cooling chamber material (distillate contact): SUS304
Input power voltage: 380V 50/60HZ  Three phase four wire five wire system (grounding wire) 5.8KW
Input compressed air: Dry and clean compressed air above 5KG
Sheet metal construction: Carbon steel powder spraying
Heating heat exchanger: SUS316coil
Evaporation type: Heat pump low-temperature evaporation
Evaporation conditions: -0.92KPA-0.097KPA temperature25-40ºC
Evaporation temperature: 25-40ºC
Steam separator: SUS304Demister
Heating and cooling technology: Heat pump circuit
Heat pump compressor: vortex
cryogen: R22
Vacuum system: Liquid ejector
Operation control: PLC and HMI intelligent control and 4G remote monitoring
Noise: 68dB (A) measured at 1M from the mechanical surface and 1.6M from the ground

 
  1. Nominal performance (factory test performance):
The data in the following table are the performance indicators obtained by using tap water as process water.
power supply unit 380V   50/HZ
Maximum output of evaporation effluent L/24h 250±10%
Absorbed power KW 2.25±10%
Heat generated by radiator KW 2.25±10%
Air flow around radiator Good ventilation Heat dissipation
Temperature at saturated evaporation Sewage: 37 ºC± 10% Steam: 36 ºC± 10% Distillate temperature: 28 ºC± 10%
 Hve-P249heat Pump Vacuum Evaporator, 250L/T Negative Pressure Heat Pump Evaporator
  1. Function description: an evaporator (temperature 25-40 ºC) for treating water-based liquid based on vacuum and heat pump technology;
Hve-P249heat Pump Vacuum Evaporator, 250L/T Negative Pressure Heat Pump Evaporator



3.1,technological process:
    The liquid to be treated is sucked into distilling chamber D01, and vacuum is generated in the distilling chamber under the action of G01. The feedback signal from EV01 liquid level sensor is sent to PLC, and the PLC controls VM02 to open and close. The bottom of the distillation chamber consists of a coil heat exchanger E01. The refrigerant R134A of the heat pump circuit flows into the heat exchanger E01. The liquid to be treated contacts the E01 heat exchanger and is heated to boil. The steam rises through the demister. The refrigerant generated by the steam and E02 exchanges heat and cold through the circulating water in G02 and F01. The distillate and non condensable gas are taken together and sent to the storage tank D02 by G01. The distillate is discharged through overflow, and the non condensable gas and liquid are discharged together. The concentrate is discharged through valves VM01 and G03 after the cycle is completed;

3.2,vacuum system
   The vacuum system is composed of a multi-stage centrifugal pump and an ejector. The ejector adopts the Venturi principle and uses the distillate produced by the evaporator as the motor power fluid. The efficiency of the vacuum system depends on the temperature of the motor fluid. The opening of valve VM03 can destroy the vacuum in the evaporation chamber;

3.3,Heat pump circuit
   The heat required for evaporating liquid and the cooling capacity required for condensing steam are provided by the heat pump circuit. The refrigerant in the gas phase is compressed by the compressor, flows into the E01 plate heat exchanger, and releases the heat to the liquid. The refrigeration after releasing the heat is cooled. The auxiliary fin radiator K02 starts the secondary heat exchange according to the set conditions, and any excess heat is released to the environment. The liquid phase refrigerant flows through the filter to the expansion valve. After throttling, the refrigerant with low temperature and pressure is generated, which is used to condense the cooling capacity required by the steam;

3.4,Auxiliary liquid 
Foam inhibitor is supplied by valve VM04;

Options and Accessories
Serial No description configuration remarks
1 Foam inhibitor liquid shortage warning Standard configuration  
2 Original liquid barrel Optional Standard configuration of suction reminder
3 Concentrate barrel Optional Optional concentration tank full reminder
4 Distillate barrel Optional Optional distillate full warning
 
  1. Size, weight, packaging, storage and handling
type size(MM) weight(KG)
Unpacked 1535*900*1900 545
   If the equipment needs to be stored for a long time before installation, it should be kept indoors, in a clean and dry area, with a temperature range of 5-35 ºC and a relative humidity of 20% - 80%; The transportation of evaporation requires the help of a forklift of appropriate length;
  1. Ambient conditions, ventilation and auxiliary cooling
Condition Type Working conditions
10-40ºC Normal
0ºC<temperature<10ºC It is allowed to start. Precautions: prevent icing
>40ºC Get in touch with Liheda;
  1. Installation requirements
The machine is designed to be installed in a safe area with non corrosive atmosphere. The indoor horizontal surface is flat and can support the weight of the equipment itself; There must be a space around the equipment to ensure smooth operation of users and maintenance personnel, and allow cold air to pass through the ventilator. The characteristics of liquid connections and pipes are as follows:
Serial No description type caliber requirement
1 Liquid inlet to be treated Reserved internal teeth 1 inch internal tooth  
2 Concentrate discharge outlet Reserved internal teeth 1 inch internal tooth  
3 Defoamer inlet Reserved air pipe orifice 6 cm straight plug  
4 Distillate outlet Reserved internal teeth 6 internal teeth  
5 Tap water inlet Reserved internal teeth 1 inch internal tooth  
  The non condensable gas that may be discharged is discharged into the pipeline through the distillate.
The following facilities are required for equipment operation:
Type requirement condition size characteristic
compressed air Clean and dry Above 4BAR 8 cm air pipe and connector  
electric energy 380V 50/60HZ 3-phase 5-wire system Power: 2.8KW Cable line 4 square meters
Hve-P249heat Pump Vacuum Evaporator, 250L/T Negative Pressure Heat Pump Evaporator


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Trading Company
Number of Employees
8
Registered Capital
739010.91 USD